Fitmore hip stem

WebJan 7, 2024 · On the other hand, studying the metaphyseal-anchored Fitmore hip system (Fitmore®, Zimmer Inc., Warsaw, IN, USA), Gustke described subsidence of more than 2 mm on plain radiographs in 34% of 100 examined THA after a mean follow-up of 1.3 years. However, none of these implants had to be revised during this short follow-up . In our … WebJan 6, 2016 · The Fitmore Hip Stem (Zimmer, Winterthur, Switzerland) is a curved, uncemented triple-tapered stem made from titanium alloy. Proximally, it has a titanium vacuum plasma spray coating, while the …

Class 2 Device Recall FITMORE HIP STEM - Food and Drug Administration

WebApr 1, 2014 · DOI: 10.1016/j.jocd.2013.11.001 Corpus ID: 2830715; Osseointegration of Fitmore stem in total hip arthroplasty. @article{Gasbarra2014OsseointegrationOF, title={Osseointegration of Fitmore stem in total hip arthroplasty.}, author={Elena Gasbarra and Monica Celi and Fabio Luigi Perrone and Riccardo Iundusi and Luigia Anna Di … WebDec 20, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option . A cementless titanium press-fit cup with or without screws ... chipping mix concrete https://britfix.net

Zimmer Fitmore Hip Stem - Which Medical Device

WebJan 10, 2024 · A total of 241 hips in patients who received total hip arthroplasty (THA) using the Fitmore stem between Jan 2014 and Jun 2016 at the hospital were eligible for … WebApr 1, 2014 · Fitmore ® Hip Stem is a curved uncemented stem with a trapezoidal cross-section, which is coated proximally with Ti-VPS (Titanium Vacuum Plasma Spray) and … WebOct 10, 2024 · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented - Product Code LZO: Product: Fitmore Hip Stem, hip prosthesis, … grape nuts many parts are edible

Osseointegration of Fitmore stem in total hip arthroplasty.

Category:Hip Zimmer Biomet EU

Tags:Fitmore hip stem

Fitmore hip stem

Prospective 5-year study with 96 short curved Fitmore™ hip

WebIn 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively CONCLUSION: Digital templating for the Fitmore ® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing ... WebSep 23, 2024 · The Fitmore ® hip stem shows a high primary stability comparable to straight stem systems . The survival rate of the Fitmore ® hip stem after 8.6 years is reported with 99.6% (95% CI 97.1–99.9%) for the endpoint of “stem revision due to aseptic loosening”. However, the long-term impact of a low Canal Fill Index because of a high …

Fitmore hip stem

Did you know?

WebThe Zimmer Biomet primary hip portfolio encompasses femoral and acetabular systems, instruments and support services to address the distinct needs of individual patients, while simplifying the surgical workflow. ... Fitmore® Hip Stem. CPT® 12/14 Femoral System. Avenir® Hip System. Acetabular Reconstruction. G7 ® Acetabular System. WebCorrespondence: Bernd Alexander Ishaque, Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, Giessen, 35392, Germany, Tel +49 641 98542914, Fax +49 641 98542969, Email [email protected]. Abstract: Short stem hip replacement has …

WebMay 27, 2024 · Background An increased occurrence of cortical hypertrophy (CH) was observed 1–2 years after implanting short curved Fitmore hip stems. There are no … WebHip Replacement Products. From joint preservation to complex revision arthroplasty, Zimmer Biomet offers a comprehensive portfolio of hip products that combine rich clinical heritage with modern technological …

WebCurrently, an increasing number of younger patients undergo total hip arthroplasty surgery. This has led to a minimal invasive approach and the use of short, bone preserving, … WebDec 1, 2015 · The Fitmore® hip stem (Zimmer, Warsaw, IN) (Fig. 1) is a curved, uncemented, short-stem prosthesis which was introduced into clinical routine in 2007. Its curved design is thought to transmit load proximally and …

WebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the …

WebJan 6, 2016 · The Fitmore Hip Stem (Zimmer, Winterthur, Switzerland) is a curved, uncemented triple-tapered stem made from titanium alloy. Proximally, it has a titanium vacuum plasma spray coating, while the distal part is rough-blasted. The anchorage concept is based on apposition to the calcar supported by the medial curvature, which is available … chipping methodologyWebFor both stems, a proximal fixation was found. However, for the mediolateral bending behavior, we observed a significantly (p < 0.01) higher flexibility of the CLS stem compared to the Fitmore stem. Conclusion: Hip stem implantation may induce remodelling of the periprosthetic bone structure. Considering the proximal fixation of both stems ... grape nuts name originWeb5 Fitmore Hip System - Ordering Information Fitmore General Instrument Set Product Description Size Quantity Product Number Fitmore Curved Hand Rasp – 1 00-7942-020 … grape-nuts nutrition informationWebApr 1, 2024 · The shorter stemmed prostheses (Fitmore(®) and our stem) performed better than the longer stemmed prosthesis (VerSys(®)). Conclusions: This is the first study to investigate the femoral ... grape-nuts nutritional informationWebJun 30, 2014 · Share on Social Media. Facebook. Twitter grape nuts microwaveWebThe Zimmer femoral stems and necks are metal alloy implants used for hip replacements that allow the surgeon to fit the implant specifically to the patient. During hip replacement surgery, the damaged portions of the … grape nuts off brandWebThe aims of this study were to identify whether the bone mineral density (BMD) of the proximal femur increases following hip revision with a metaphyseal-fixation femoral stem and to identify the factors associated with BMD recovery. Methods: This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal ... chipping nedir inşaat